5-52 Emergency power conservation recovery procedures
Emergency power conservation
Restoring the maintenance trunk modules to service
4
5
At the MAP terminal
6
7
8
9
10
11
12
13
297-8021-545 Standard 14.02 May 2001
Power up the NT2X09 power converter in slot 20 as follows:
a
Pull up and set the handle of the POWER switch to the ON position.
b
Press the RESET button on the power converter until the CONVERTER
FAIL LED goes off.
c
Release the RESET button.
Replace the NT0X70 processor and memory card.
To post the maintenance trunk module (MTM), type
>POST
MTM
pm_no
and press the Enter key.
where
pm_no
is the peripheral module (PM) identification number (0 to 999)
To load the PM, type
>LOADPM
and press the Enter key.
To return the PM to service, type
>RTS
and press the Enter key.
To access the trunk test position (TTP) level of the MAP display, type
>TRKS;TTP
and press the Enter key.
To post the TTP circuits that associate with the MTM, type
>POST
P
MTM
pm_no
and press the Enter key.
where
pm_no
is the PM identification number (0 to 999)
To return the circuits that you busy in step 10 to service, type
>RTS
ALL
and press the Enter key.
Repeat steps 1 to 11 for each MTM that you powered down to conserve
emergency power.
The procedure is complete.