46
Contact the next level of support to determine if you can synchronize the
CPUs.
If you
can synchronize the CPUs
cannot synchronize the CPUs
47
Determine if the inactive CPU jammed.
Note: The word yes under the Jam header indicates that the CPU
jammed. The area is blank if the CPU did not jam.
If the inactive CPU
jammed
did not jam
At the CM reset terminal for the INACTIVE CPU
48
To release the jam on the inactive CPU, type
>\RELEASE
and press the Enter key.
RTIF response:
JAM RELEASE DONE
At the MAP terminal
49
To synchronize the CPUs, type
>SYNC
and press the Enter key.
If the response
indicates the SYNC command passed
indicates a problem with mismatches makes the
CPUs not in sync. Analyze the mismatch logs before
you sync again.Do you wish to continue?Please Con-
firm("YES", "Y", or "NO", "N")(SuperNode/Super-
Node SE series 70 only)
is other than listed here
50
(SuperNode/SuperNode SE Series 70 only)
To deny the action, type
>NO
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Booting a DMS switch
JAM
Do
step 47
step 52
Do
step 48
step 49
Do
step 52
step 50
step 51
2-15
(continued)