Advertisement

Recovering from a dead system in a SuperNode switch
and press the Enter key.
169
To access the CM level of the MAP display, type
>CM
and press the Enter key.
170
Determine if the CPUs are in sync.
171
Determine from the next level of support if you have permission to
synchronize the CPUs.
172
Determine if the inactive CPU jammed.
At the CM reset terminal for the INACTIVE CPU
173
To release the jam on the inactive CPU, type
>\RELEASE
and press the Enter key.
RTIF response:
JAM RELEASE DONE
If the SYNC command
succeeded
failed
Note: A dot symbol under the Sync header indicates that the CPUs are in
sync. The word no indicates that the CPUs are not in sync.
If the CPUs
are in sync
are not in sync
If you
have permission to synchronize
the CPUs
do not have permission to syn-
chronize the CPUs
Note: The word yes under the Jam header indicates that the CPU
jammed. The area is blank if the CPU did not jam.
If the inactive CPU
jammed
did not jam
JAM
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Do
step 169
step 183
Do
step 176
step 171
Do
step 172
step 176
Do
step 173
step 174
2-83