Restoring a SuperNode SE ENET to duplex operation
Example of a MAP response:
Request to TRNSL ENET Plane:0 Shelf:00 submitted.
Request to TRNSL ENET Plane:0 Shelf:00 passed.
ENET Plane:0 Shelf:00 MS:0 and 1 Card:05 Link:00 Port:000
10
Note the card number and link number.
11
To access the MS Shelf level of the MAP display, type
>MS;SHELF;CHAIN
and press the Enter key.
where
12
To return the head card in the associated chain on MS 0 to service, type
>RTS
and press the Enter key.
where
13
To return the head card in the associated chain on MS 1 to service, type
>RTS
and press the Enter key.
where
14
To access the network System level of the MAP display, type
>NET;SYSTEM
and press the Enter key.
Example of a MAP display:
SYSTEM
ShelfPlane 0Plane 1
00 O
15
To manually busy the shelf that you powered down to conserve power, type
>BSY
and press the Enter key.
where
MAP response:
Emergency power conservation recovery procedures
card_no
card_no
is the card number you noted in step 10
0
LINK
link_no
link_no
is the link number you noted in step 10
1
LINK
link_no
link_no
is the link number you noted in step 10
plane_no
shelf_no
plane_no
is the ENET plane number (0 or 1)
shelf_no
is the ENET shelf number (0 or 1)
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
5-81
(continued)