5-134 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one LGC, LTC, and DTC unit
10
11
12
13
14
15
297-8021-545 Standard 14.02 May 2001
LINK 0: ENET 0
LINK 1: ENET 1
LINK 2: ENET 0
LINK 3: ENET 1
LINK 4: ENET 0
LINK 5: ENET 1
LINK 6: ENET 0
LINK 7: ENET 1
Determine if the network on your switch is a junctored network (JNET) or
enhanced network (ENET).
If the network
is JNET
is ENET
Determine the XPM unit that is manual busy (0 or 1) . Note the speech link
numbers (0 to 31) that associate with the manual busy XPM. Even numbered
speech links (0, 2, 4 ... 30) associate with XPM unit 0. Odd numbered speech
links (1, 3, 5 ... 31) associate with XPM unit 1.
Note: Speech link numbers 5 to 30 do not appear in the example in step 9.
Record the network plane number, network module (pair) number, and the
network link number. Record these numbers for each speech link recorded
in step 11.
Note: Speech link 2 associates with the network plane 0, network module
number 1, and network link number 4. The association appears in the
JNET example in step 9.
To access the NET level of the MAP display, type
>NET
and press the Enter key.
To access the network link level for the first network link that you will busy,
type
>LINKS
n
and press the Enter key.
where
n
is the network module number recorded in step 12
To manually busy the first network link, type
>BSY
plane_no
link_no
and press the Enter key.
where
0 14 01 0;CAP MS;Status:OK
0 24 01 0;CAP MS;Status:OK
0 14 01 1;CAP MS;Status:OK
0 24 01 1;CAP MS;Status:OK
0 14 01 2;CAP MS;Status:OK
0 24 01 2;CAP MS;Status:OK...
0 14 01 3;CAP MS;Status:OK
0 24 01 3;CAP MS;Status:OK
Do
step 11
step 18
(continued)