Nortel DMS-100 Manual page 205

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

3-38 Node level recovery procedures
Recovering SuperNode SE application specific units
16
17
18
19
20
21
297-8021-545 Standard 14.02 May 2001
Manually busy unit zero of the affected NIU by typing
>BSY
UNIT
0
FORCE
and pressing the Enter key.
Load the NIU unit by typing
>LOADPM
UNIT
0
and pressing the Enter key.
If the LOADPM command
passed
failed
Return the NIU unit to service by typing
>RTS
UNIT
0
and pressing the Enter key.
If the RTS command
passed
failed
Determine if the other unit of the posted NIU is in service.
If
both units of the posted NIU are
in service
the other unit of the posted NIU
is not in service
Manually busy the NIU unit by typing
>BSY
UNIT
1
FORCE
and pressing the Enter key.
Load the NIU unit by typing
>LOADPM
UNIT
1
and pressing the Enter key.
If the LOADPM command
passed
failed
(continued)
Do
step 18
step 33
Do
step 19
step 33
Do
step 23
step 20
Do
step 22
step 33

Advertisement