Restoring the LGCs, LTCs, and DTCs to duplex operation
where
plane_no
28
Repeat steps 25 to 27 for each speech link recorded in step 22. Continue the
procedure.
29
To reload the manual busy XPM unit, type
>PM;LOADPM
and press the Enter key.
where
unit_no
30
To return the XPM unit to service, type
>RTS
and press the Enter key.
31
Repeat steps 1 to 30 for each LGC, LTC, and DTC unit that you power down
to conserve emergency power.
32
Return to the procedure Recovering from emergency power conservation
measures in this document. Proceed when the step-action procedure directs
you to go.
Emergency power conservation recovery procedures
Emergency power conservation measures
is the ENET plane number
UNIT
unit_no
is the number of the manual-busy unit (0 or 1)
UNIT
unit_no
DMS-100 Family NA100 Recovery Procedures LET0015 and up
5-39
(end)