2-8 System level recovery procedures
Booting a DMS switch
At the CM reset terminal for the ACTIVE CPU
17
18
19
20
297-8021-545 Standard 14.02 May 2001
(continued)
If A1
does not flash after 15 min
DANGER
BOOT command
A CPU mismatch occurs if you use the BOOT command
when the CPUs are InSync. Mismatch handling and
mismatch recovery can change the state of one of both CPUs.
For example, the active CPU can reset the mate CPU during
mismatch handling or recovering. Any in-progress
commands such as BOOT terminate, as a result.
To override the active CPU, type
>\OVERRIDE
and press the Enter key.
RTIF response:
TEMP. RESET/JAM ENABLE
Boot the active CPU by typing
>\BOOT SLM_no
and pressing the Enter key.
where
slm_no
is the number of the SLM (0 or 1) with the required tape load
To confirm the command, type
>YES
and press the Enter key.
RTIF response:
BOOT INITIATED
Monitor the CM reset terminal for the active CPU to determine if the switch
booted.
Note: When the switch boots, the reset terminal displays the response
Booting, followed by different diagnostic messages. Alphanumeric
Do
Repeat step 6, or contact your
next level of support.