Restoring a SuperNode SE ENET to duplex operation
where
21
To return all matrix cards to service, type
>RTS
and press the Enter key.
where
22
To access the Network level, type
>NET
and press the Enter key.
23
To clear the deload condition on cards on the shelf that you powered down to
conserve emergency power, type
>DELOAD
and press the Enter key.
where
MAP response:
Request to CLEAR DELOAD ENET Plane:0 Shelf:00 submitted.
Request to CLEAR DELOAD ENET Plane:0 Shelf:00 passed.
24
Determine if a link interface unit (LIU) is present on the enhance network and
Interface (ENI) shelf in the single core cabinet (SCC). If an LIU is present, the
LIUs reside in ENI shelf slots 7 to 9, and 30 to 32.
If an LIU is
present
not present
25
To access the F-bus level, type
>MS;SHELF;CARD
and press the Enter key.
26
To return to service the F-bus connected the ENET plane that you powered
down, type
>RTS
and press the Enter key.
where
Emergency power conservation recovery procedures
plane_no
is the network plane number (0 or 1)
plane_no
ALL
plane_no
is the network plane number (0 or 1)
plane_no
CLEAR
plane_no
is the ENET plane number (0 or 1)
12
ms_no
FBUS
DMS-100 Family NA100 Recovery Procedures LET0015 and up
Emergency power conservation
Do
step 26
step 28
5-83
(continued)