Recovering AMA data without DIRP block numbers
Recovering AMA data without DIRP block numbers
At your current location
1
Contact your data center. Obtain the following information:
the time frame of the missing AMA data
the sequence number of the DPP block that the data center received
before the DPP power failure
the sequence number of the DPP block that the data center received after
the DPP power failure
Note: The sequence numbers this document refers to are DPP reference
numbers. The DMS or data center do not assign these sequence
numbers.
At the MAP terminal
2
To access the DPP level of the MAP, type
>MAPCI;MTC;IOD;DPP
and press the Enter key.
3
To access the DIRP logs, type
>LOGUTIL;OPEN
and press the Enter key.
4
To enable the printer, type
>RECORD
and press the Enter key.
where
device
5
To obtain a print of the DPP AMA block that the data center received before
the DPP power failure, type
>IDXMAINT
Recovery procedures for individual devices and services
CAUTION
Possible loss or damage of AMA data
The operating company uses automatic message accounting
(AMA) data to produce billings. Loss or damage of AMA
data results in revenue loss for the operating company. If you
do not use this procedure or do not follow this procedure
exactly, you can lose or damage AMA data.
AMA
DIRP
START
ONTO
is the printer type
EXAMINE
AMA
DMS-100 Family NA100 Recovery Procedures LET0015 and up
device
PACKED
first_sequence_no
4-61
(continued)