Emergency shutdown of one LIM unit on each LPP
Emergency shutdown of one LIM unit on each LPP
At the MAP terminal
1
To access the PM level of the MAP display, type
>MAPCI;MTC;PM
and press the Enter key.
Example of a MAP display:
PM
2
To post the LIM that contains the unit that you will power down, type
>POST
and press the Enter key.
where
lim_no
is the number of the LIM that you will post (0 to 16)
Example of a MAP response:
LIM 1
Unit0: ManB
Unit1:
Emergency power conservation recovery procedures
Emergency power conservation
WARNING
Potential service interruption or extended outage
Nortel recommends that you contact the Emergency
Technical Assistance Services (ETAS) or the next level of
support before you perform this procedure.
WARNING
Potential loss of service or extended outage
Perform this procedure to conserve emergency backup
power. Do not use this procedure or sections of this
procedure for equipment maintenance purposes.
SysB
ManB
OffL
1
10
LIM
lim_no
ISTB
Links_OOS Taps_OOS
2
.
.
DMS-100 Family NA100 Recovery Procedures LET0015 and up
CBsy
ISTb
12
0
6
16
.
5-145
(continued)