5-148 Emergency power conservation recovery procedures
Emergency power conservation
Emergency shutdown of one LIM unit on each LPP
At the LPP
8
9
297-8021-545 Standard 14.02 May 2001
unit_no
is the number of the LIM unit (0 or 1)
WARNING
Static electricity damage
Wear a wrist strap that connects to a wrist-strap grounding
point on the frame supervisory panel (FSP) or the modular
supervisory panel (MSP) to handle circuit cards. The wrist
strap protects the cards against static electricity damage.
Press down and release the power switch on the faceplate of the NT9X30
power converter. Slot 4 for LIM unit 0 and slot 36 for LIM unit1 contain the
NT9X30 power converter. This procedure powers down the LIM unit busied
in step 7.
Note: The CONVERTER OFF LED goes on when you power down the
NT9X30 power converter.
Return to the procedure Emergency power conservation—Shutdown in this
document. Proceed when the step-action procedure directs you to go.
(end)