Nortel DMS-100 Manual page 54

Hide thumbs Also See for DMS-100:
Table of Contents

Advertisement

At the CM reset terminal for the ACTIVE CPU
13
To override the active CPU, type
>\OVERRIDE
and press the Enter key.
RTIF response:
TEMP. RESET/JAM ENABLE
14
Boot the active CPU by typing
>\BOOT SLMslm_noT
and pressing the Enter key.
where
slm_no
is the number of the SLM (0 or 1) with the required tape load
15
To confirm the command, type
>YES
and press the Enter key.
RTIF response:
BOOT INITIATED
16
Monitor the CM reset terminal for the active CPU to determine if the switch
booted.
Note: When the switch boots, the reset terminal displays the response
Booting, followed by different diagnostic messages. Alphanumeric
addresses appear in the status bar. When the switch boot finishes, A1
flashes in the status bar.
If A1
flashes
DMS-100 Family NA100 Recovery Procedures LET0015 and up
System level recovery procedures
Booting a DMS switch
DANGER
BOOT command
A CPU mismatch occurs if you use the BOOT command
when the CPUs are InSync. Mismatch handling and
mismatch recovery can change the state of one of both CPUs.
For example, the active CPU can reset the mate CPU during
mismatch handling or recovering. Any in-progress
commands such as BOOT terminate, as a result.
Do
step 37
2-7
(continued)