2-100 System level recovery procedures
Recovering from a dead system in a SuperNode SE switch
At the ENET frames
73
74
75
76
77
78
79
At the MAP terminal
80
297-8021-545 Standard 14.02 May 2001
Locate the NT9X31 power converters for the enhanced network (ENET)
shelves.
Note: Slots 1F and 33F on the ENET shelf contain the NT9X31 power
converters.
Ensure that the power converters are off. If they are not off, turn off the power
converters by pushing down and releasing the power switches located on the
faceplate of each converter.
Turn on the NT9X31 power converters. Lift and release the power switches
on the faceplates of the converters to turn on the NT9X31 power converters.
Locate the NT9X30 power converters for the ENET shelves.
Note: Slots 4F and 36F on the ENET shelf contain the NT9X30 power
converters.
Turn on the NT9X30 power converters. Lift and release the power switches
on the faceplates of the converters to turn on the NT9X30 power converters.
Determine if all the converters powered up correctly. The indication is that all
the Converter Off lights go off.
If all the converters
powered up
did not power up
Power up the ENET frame. Perform the procedure Clearing an Ext FSP
DPCC cabinet major alarm in Alarm and Performance Monitoring
Procedures
Complete the procedure and return to this point.
Go to step 73.
To access the SRSTATUS level of the MAP display, type
>SRSTATUS
and press the Enter key.
Example of a MAP display:
SRSTATUS
OVERALL STATUS Pend:
0
Quit
VIEW: SYSTEM
2
View_
Pend InPrg
3
List_ MS
0
4
NET
0
5
SER1
0
6
SER2
1
7
SER3
11
8
9
SRSTATUS:
Do
step 80
step 79
18%
InProg: 9%
Comp
Fail
0
2
0
IOD
0
6
0
Other 21
1
6
0
1
60
1
8
30
1
(continued)
Comp: 70%
Fail: 3%
11:52:34
Pend
InPrg
Comp
Fail
5
5
30
3
13
2
3

Advertisement

Table of Contents
loading

Table of Contents