D-Link xStack DGS-3324SRi Command Line Interface Reference Manual page 59

High-density layer 3 intelligent gigabit switch
Hide thumbs Also See for xStack DGS-3324SRi:
Table of Contents

Advertisement

config snmp system_contact
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure the Switch contact to "
config snmp system_location
Purpose
Syntax
Description
Parameters
Restrictions
xStack Gigabit Layer 3 Switch Command Line Interface Manual
DGS-3324SRi:4#disable snmp authenticate_traps
Command: disable snmp authenticate_traps
Success.
DGS-3324SRi:4#
Used to enter the name of a contact person who is responsible for
the Switch.
config snmp system_contact {<sw_contact>}
The config snmp system_contact command is used to enter the
name and/or other information to identify a contact person who is
responsible for the Switch. A maximum of 255 character can be
used.
<sw_contact> - A maximum of 255 characters is allowed. A NULL
string is accepted if there is no contact.
Only administrator-level users can issue this command.
M I S D e p a r t m e n t I I
DGS-3324SRi:4#config snmp system_contact MIS Department II
Command: config snmp system_contact MIS Department II
Success.
DGS-3324SRi:4#
Used to enter a description of the location of the Switch.
config snmp system_location {<sw_location>}
The config snmp system_location command is used to enter a
description of the location of the Switch. A maximum of 255
characters can be used.
<sw_location> - A maximum of 255 characters is allowed. A NULL
string is accepted if there is no location desired.
Only administrator-level users can issue this command.
":