Loopback Test Failure (Active) - Dodge ZB 2005 Service Manual

Table of Contents

Advertisement

Symptom:

LOOPBACK TEST FAILURE (ACTIVE)

When Monitored and Set Condition:
LOOPBACK TEST FAILURE (ACTIVE)
When Monitored: When the A/C - Heater Control Module executes an internal loopback
test.
Set Condition: If the A/C - Heater Control Module fails to send a message, or none of the
expected messages arrive for 5 seconds, an internal loopback test is executed. If the
internal loopback test fails, the DTC will set.
CHECK FOR ADDITIONAL HVAC DTCS
A/C - HEATER CONTROL MODULE
TEST
1
Turn the ignition on.
With the DRBIII , read HVAC DTCs.
Does the DRBIII display additional HVAC DTCs?
Yes → Return to the symptom list and choose the symptom(s).
No
POSSIBLE CAUSES
ACTION
Perform BODY VERIFICATION TEST - VER 1.
→ Replace the A/C - Heater Control Module in accordance with the
Service Information.
Perform BODY VERIFICATION TEST - VER 1.
221
HEATING & A/C
APPLICABILITY
All

Advertisement

Table of Contents
loading

Table of Contents