Passenger Door Lock Circuit Short To Ground - Dodge ZB 2005 Service Manual

Table of Contents

Advertisement

POWER DOOR LOCKS/RKE
Symptom:

PASSENGER DOOR LOCK CIRCUIT SHORT TO GROUND

When Monitored and Set Condition:
PASSENGER DOOR LOCK CIRCUIT SHORT TO GROUND
When Monitored: At all times when battery power is supplied to the Body Control
Module.
Set Condition: When the BCM senses voltage on the passenger door switch mux circuit
below 0.7 volts for over 10 seconds.
DTC PRESENT
PASSENGER DOOR SWITCH MUX CIRCUIT SHORT TO GROUND
PASSENGER DOOR LOCK SWITCH SHORT TO GROUND
PASSENGER INTERIOR DOOR HANDLE SWITCH SHORT TO GROUND
PASSENGER EXTERIOR DOOR HANDLE SWITCH SHORT TO GROUND
PASSENGER DOOR SWITCH MUX WIRE SHORT TO THE DRIVER DOOR SWITCH RETURN.
BODY CONTROL MODULE - PASSENGER DOOR SWITCH MUX CIRCUIT SHORT TO GROUND
TEST
1
NOTE: When this code is present, the VTSS indicator will stay on solid during the
arming process.
With the DRBIII , record and erase DTC's.
Cycle the ignition switch from ON to OFF to ON.
With the DRBIII , read DTC's.
Lower the passenger door window.
Remove the key and operate all the passenger door switches several times while
monitoring the DRBIII .
Wait 10 seconds.
Does the DRBIII
GROUND?
Yes → Go To 2
→ Using the wiring diagram/schematic as a guide, inspect the
No
2
Disconnect the Body Control Module C3 and C4 connectors.
Measure the resistance between ground and the Passenger Door Switch Mux circuit
in the BCM C3 connector.
Is the resistance below 300.0 ohms?
Yes → Repair the Passenger Door Switch Mux circuit for a short to
→ Go To 3
No
POSSIBLE CAUSES
ACTION
display PASSENGER DOOR LOCK CIRCUIT SHORT TO
wiring and connectors for an intermittent condition.
Perform BODY VERIFICATION TEST - VER 1.
ground
Perform BODY VERIFICATION TEST - VER 1.
310
APPLICABILITY
All
All

Advertisement

Table of Contents
loading

Table of Contents