Symptom List:
P0351-IGNITION COIL #1 PRIMARY CIRCUIT
P0352-IGNITION COIL #2 PRIMARY CIRCUIT
P0353-IGNITION COIL #3 PRIMARY CIRCUIT
P0354-IGNITION COIL #4 PRIMARY CIRCUIT
P0355-IGNITION COIL #5 PRIMARY CIRCUIT
Test Note: All symptoms listed above are diagnosed using the same tests.
The title for the tests will be P0351-IGNITION COIL #1 PRI-
MARY CIRCUIT.
When Monitored and Set Condition:
P0351-IGNITION COIL #1 PRIMARY CIRCUIT
When Monitored: With battery voltage greater than 8 volts during engine cranking or
greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils
in dwell when checked.
Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of
diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while
running to set.
P0352-IGNITION COIL #2 PRIMARY CIRCUIT
When Monitored: With battery voltage greater than 8 volts during engine cranking or
greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils
in dwell when checked.
Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of
diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while
running to set.
P0353-IGNITION COIL #3 PRIMARY CIRCUIT
When Monitored: With battery voltage greater than 8 volts during engine cranking or
greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils
in dwell when checked.
Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of
diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while
running to set.
P0354-IGNITION COIL #4 PRIMARY CIRCUIT
When Monitored: With battery voltage greater than 8 volts during engine cranking or
greater than 12 volts with engine running, engine rpm less than 2016, and none of the coils
in dwell when checked.
Set Condition: Peak current is not achieved with battery based dwell plus 1.5 msec of
diagnostic offset. It takes less than 3 seconds during cranking or up to 6 seconds while
running to set.