Symptom:

DRIVER WINDOW UP OUTPUT SHORT TO GROUND

When Monitored and Set Condition:
DRIVER WINDOW UP OUTPUT SHORT TO GROUND
When Monitored: Whenever the ignition is in the Run or Accessory position.
Set Condition: When the BCM turns on the Driver Window Up circuit and detects a
voltage of less than 0.5 volts for over 125 milliseconds, this code will set.
DTC PRESENT
MOTOR SHORTED
DRIVER WINDOW UP DRIVER WIRE SHORT TO GROUND
BODY CONTROL MODULE -DRIVER WINDOW UP DRIVER SHORTED
TEST
1
Turn the ignition on.
With the DRBIII , erase DTCs.
Cycle the ignition switch from Off to Run.
Try to operate the Driver Window Motor by using the Driver Window Switch.
With the DRBIII , read DTCs.
Does the DRBIII display DRIVER WINDOW UP OUTPUT SHORT TO GROUND?
Yes → Go To 2
→ The condition that caused the code to set is not present at this
No
2
Disconnect the Driver Window Motor connector.
Turn the ignition on.
With the DRBIII , erase DTCs.
Cycle the ignition switch from Off to Run.
Press the Driver Window Switch UP several times.
With the DRBIII , read DTCs.
Does the DRBIII display DRIVER WINDOW UP SHORTED TO GROUND?
Yes → Go To 3
→ Replace the Window Motor.
No
POSSIBLE CAUSES
ACTION
time. Using the wiring diagram/schematic as a guide, inspect the
wiring and connectors.
Perform BODY VERIFICATION TEST - VER 1.
Perform BODY VERIFICATION TEST - VER 1.
347
POWER WINDOWS
APPLICABILITY
All