DRIVEABILITY - GAS
P0442-EVAP LEAK MONITOR MEDIUM (0.040) LEAK DETECTED —
Continued
TEST
3
NOTE: A thorough visual inspection of the Evap system hoses, tubes, and
connections may save time in your diagnosis. Look for any physical damage
or signs of wetness at connections. The strong smell of fuel vapors may aid
diagnosis also.
To continue testing, you will need Miller Tool #8404 Evaporative Emissions Leak
Detector (EELD).
Remove the Air supply hose from the service port.
Connect the SMOKE supply tip (black hose) to the service port.
Set the smoke/air control switch to SMOKE.
NOTE: The flow meter indicator ball will not move at this point.
Press the remote smoke/air start button.
NOTE: Ensure that smoke has filled the EVAP system by continuing to press
the remote smoke/air start button, remove the vehicle fuel cap, and wait for
the smoke to exit. Once smoke is indicated reinstall the fuel cap.
NOTE: For optimal performance, introduce smoke into the system for an
additional 60 seconds; continue introducing smoke at 15 second intervals,
as necessary.
While still holding the remote smoke/air start button, use the white light (#8404-
CLL) to follow the EVAP system path, and look for the source of the leak indicated by
exiting smoke.
If a leak is concealed from view (i.e., top of fuel tank), release the remote smoke/air
start button, and use the ultraviolet (UV) black light #8404-UVL and the yellow
goggles 8404-20 to look for residual traces of dye that is left behind by the smoke.
The exiting smoke deposits a residual fluid that is either bright green or bright
yellow in color when viewed with a UV light.
Was a leak found?
Yes → Repair or replace the leaking component as necessary.
No
4
NOTE: After disconnecting the Evap Purge Solenoid vacuum connections,
inspect the lines and solenoid for any signs of contamination from the EVAP
Canister. This may indicate a faulty rollover valve. Replace/repair as
necessary.
Turn the ignition off.
Disconnect the vacuum hoses at the Evap Purge Solenoid.
Using a hand vacuum pump, apply 10 inches of vacuum to the Evap Purge Solenoid
vacuum source port on the component side.
NOTE: Monitor the vacuum gauge for at least 15 seconds.
Does the Evap Purge Solenoid hold vacuum?
Yes → Refer to the INTERMITTENT CONDITION Symptom (Diagnos-
No
ACTION
Perform POWERTRAIN VERIFICATION TEST VER - 6.
→ Go To 4
tic Procedure).
Perform POWERTRAIN VERIFICATION TEST VER - 6.
→ Replace the EVAP Purge Solenoid.
Perform POWERTRAIN VERIFICATION TEST VER - 6.
114