Act Ckt Test Passed, Overcurrent Dtcs Active; Blend Circuit Shorted To Ground; Blend Circuit Shorted To Ign Or Batt; Common Driver Shorted To Ground - Dodge ZB 2005 Service Manual

Table of Contents

Advertisement

HEATING & A/C
Symptom List:

ACT CKT TEST PASSED, OVERCURRENT DTCS ACTIVE

BLEND CIRCUIT SHORTED TO GROUND

BLEND CIRCUIT SHORTED TO IGN OR BATT

COMMON DRIVER SHORTED TO GROUND

COMMON DRIVER SHORTED TO IGN OR BATT

MODE 1 CIRCUIT SHORTED TO GROUND

MODE 1 CIRCUIT SHORTED TO IGN OR BATT

MODE 2 CIRCUIT SHORTED TO GROUND

MODE 2 CIRCUIT SHORTED TO IGN OR BATT

RECIRC CIRCUIT SHORTED TO GROUND

RECIRC CIRCUIT SHORTED TO IGN OR BATT

SHORT TOO COMPLEX

Test Note: All symptoms listed above are diagnosed using the same tests.
The title for the tests will be ACT CKT TEST PASSED, OVER-
CURRENT DTCS ACTIVE.
When Monitored and Set Condition:
ACT CKT TEST PASSED, OVERCURRENT DTCS ACTIVE
When Monitored: When the Actuator Circuit Test is executed.
Set Condition: If two or more drivelines shorted together.
BLEND CIRCUIT SHORTED TO GROUND
When Monitored: When the Actuator Circuit Test is executed.
Set Condition: This message will set if the A/C - Heater Control detects a short low on the
Blend Door Driver circuit.
BLEND CIRCUIT SHORTED TO IGN OR BATT
When Monitored: When the Actuator Circuit Test is executed.
Set Condition: This message will set if the A/C - Heater Control detects a short high on
the Blend Door Driver circuit.
COMMON DRIVER SHORTED TO GROUND
When Monitored: When the Actuator Circuit Test is executed.
Set Condition: This message will set if the A/C - Heater Control detects a short low on the
Common Door Driver circuit.
COMMON DRIVER SHORTED TO IGN OR BATT
When Monitored: When the Actuator Circuit Test is executed.
Set Condition: This message will set if the A/C - Heater Control detects a short high on
the Common Door Driver circuit.