Ramp Load Test Menu (Sub Menu)
The task list of the buttons in the "Ramp Load Test" menu is as follows.
Figure H-13
Ramp Load Test Menu
Head Speed On Ramp Specifies the head movement speed between the ramp load
Load Test
Close

Procedure of Ramp Load Positioning

Follow the procedure below to perform the ramp load positioning.
NOTE
The ramp load positioning data contains each individual data of the UP face and the
DOWN face cassette. Perform the ramp load positioning each individual HGA face, UP
face and DOWN face cassette.
Step 1. Launch the ramp load positioning utility by the following mouse procedure, then the
window as shown in Figure H-12 is displayed.
Start
Step 2. Place the HGA cassette on the HLM.
Step 3. Click on the
Step 4. Click on the
When the HGA face, UP or DOWN is mismatched between the ramp loading mechanism
and the HGA cassette, or the switch on the Aux controller is still set to "Tilt", the error
information as shown in Appendix H-14 is displayed.
Appendix H
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
position and the media load position.
Move the head in order below.
1. Move the head to the home position.
2. Move the head to the ramp load position, then load the head.
3. Move the head to the media load position with specified the head
speed.
Return to main menu.
-
Agilent Hard Disk Read Write Test System
button, then the head is unloaded.
HGA up
button, then the ramp is moved to the Ramp In position.
Ramp In
Ramp Load
Ramp Load Positioning Utility
-
Ramp Positioning Utility