Agilent Technologies E5022A Operation Manual page 133

Hard disk read/write test system
Hide thumbs Also See for E5022A:
Table of Contents

Advertisement

VEE Measurement Program Operation
Measurement
Figure 3-77
Adjacent Track Configuration Menu
Adjacent Track Pattern
9. Click the [Measure] button to start measurement.
Measurement
The upper portion of the menu shows the measurement results of the WW (Write
Display
Width), RW (Read Width), RW (Read Write) offset, Squash, Squeeze and OTRC. The
lower left side of the graph shows the Track Profile, Squeeze and OTRC waveform.
OTRC is expressed in terms [µm].
10. Click the [Return] button to return to Measure menu.
132
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Specifies the data pattern of the adjacent track.
DC and AC erase can be selected as a data
pattern.