Agilent Technologies E5022A Operation Manual page 56

Hard disk read/write test system
Hide thumbs Also See for E5022A:
Table of Contents

Advertisement

Measure R/W offset
NOTE
When parameter [Skew] is set below -30 degrees the E5022/E5023 system can not
guarantee a track offset of ± 6µm, this could result to an error
"hpe5022_ERROR_INV_PARAMETER". When the skew angle is set below -30 degrees
the user may need to uncheck the [Measure R/W offset] parameter or set the range of the
background track offset to a value lower than ± 6µm to avoid generating an error. Refer to
"hpe5022_headPosition" function of the programming manual for details.
NOTE
When you set the Track #, you must properly specify the parameters in the Data Area and
Drive frames from the [Spinstand] menu. This will automatically compute and set the
radius and skew angle. When you specify a new [Radius] the track number nearest to the
specified value will appear as the new Track #.
5. Click the [Return] button to return to main menu.
Chapter 3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
VEE Measurement Program Operation
Sets the read/write offset automatically even if
the head position is changed. When this
parameter is checked, track profile
measurement is performed on background just
after head position is changed, then [Write
Offset] and [Read Offset] parameters are
updated to the appropriate values. Click the
[Setting] button to set the parameters for
background track profile. It is better to
uncheck this parameter if 'Skew' is set below
-30 degrees.
Setup Menu