VEE Measurement Program Operation
Measurement
Stop
Step
NOP
8. Click [Band Erase] button to open the Band Erase Configuration menu.
Figure 3-82
Band Erase Configuration menu
Band Erase Range
Band Erase Pitch
Figure 3-83
Parameter of Band Erase
9. Click [Adjacent Track Config] button to set the data pattern of the adjacent track.
136
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Specifies the stopping point of the track offset
in building the track profile. This point is
defined as the distance in [µm] from the track
center.
Specifies the step by which the head is moved
while measuring TAA in order to build the
track profile. By setting this parameter with
Offset Start and Offset Stop, Offset NOP will
be computed and updated automatically.
Specifies the number of offset points. By
setting this parameter with Offset Start and
Offset Stop, Offset Step will be computed and
updated automatically.
Specifies the range for band erase.
Specifies the erase pitch for band erase. Erase
pitch is the distance between the centers of
two adjacent tracks.