Agilent Technologies E5091A User Manual

Multiport test set
Table of Contents

Advertisement

Quick Links

Caution
Do not exceed the operating input power, voltage, and current
level and signal type appropriate for the instrument being used, refer to
your instrument's Function Reference.
Electrostatic discharge(ESD) can damage the highly sensitive
microcircuits in your instrument. ESD damage is most likely to occur as
the test fixtures are being connected or disconnected. Protect them from
ESD damage by wearing a grounding strap that provides a high
resistance path to ground. Alternatively, ground yourself to discharge any
static charge built-up by touching the outer shell of any grounded
instrument chassis before touching the test port connectors.

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies E5091A

  • Page 1 Caution Do not exceed the operating input power, voltage, and current level and signal type appropriate for the instrument being used, refer to your instrument's Function Reference. Electrostatic discharge(ESD) can damage the highly sensitive microcircuits in your instrument. ESD damage is most likely to occur as the test fixtures are being connected or disconnected.
  • Page 2 When you notice any of the unusual conditions listed below, immediately terminate operation and disconnect the power cable. Contact your local Agilent Technologies sales representative or authorized service company for repair of the instrument. If you continue to operate without repairing the instrument, there is a potential fire or shock hazard for the operator.
  • Page 3 Herstellerbescheinigung GER  AUSCHEMISSION < 70 dB am Arbeitsplatz normaler Betrieb nach DIN 45635 T. 19 Manufacturer's Declaration ACOUSTIC NOISE EMISSION < 70 dB operator position normal operation per ISO 7779...
  • Page 4 This product complies with the essential requirements of the following applicable European Directives, and carries the CE marking accordingly: The Low Voltage Directive 73/23/EEC, amended by 93/68/EEC The EMC Directive 89/336/EEC, amended by 93/68/EEC To obtain Declaration of Conformity, please contact your local Agilent Technologies sales office, agent or distributor.
  • Page 5 ・ This equipment is tested with stand-alone condition or with the combination with the accessories supplied by Agilent Technologies against the requirement of the standards described in the Declaration of Conformity. If it is used as a system component, compliance of related regulations and safety requirements...
  • Page 7 Agilent E5091A Multiport Test Set User’s Guide Third Edition Agilent Part No. E5091-90020 November 2005...
  • Page 8 This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Agilent Technologies. Microsoft®,MS-DOS®,Windows®,Visual C++®,Visual Basic®,VBA® and Excel® are registered UNIX is a registered trademark in U.S.
  • Page 9 The E5091A complies with INSTALLATION CATEGORY II as well as POLLUTION DEGREE 2 in IEC61010-1. The E5091A is an INDOOR USE product. NOTE The LEDs in the E5091A are Class 1 in accordance with IEC60825-1, CLASS 1 LED PRODUCT NOTE This equipment is MEASUREMENT CATEGORY I (CAT I).
  • Page 10 safety features are maintained in operational condition. • Dangerous Procedure Warnings Warnings, such as the example below, precede potentially dangerous procedures throughout this manual. Instructions contained in the warnings must be followed. WARNING Dangerous voltage levels, capable of causing death, are present in this instrument. Use extreme caution when handling, testing, and adjusting this instrument.
  • Page 11 Certification Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institution’s calibration facility or by the calibration facilities of other International Standards Organization members.
  • Page 12 Typeface Conventions Sample (bold) Boldface type is used when a term is defined or emphasized. Sample (Italic) Italic type is used for emphasis and for titles of manuals and other publications. menu/button/box/tab Indicates a menu/button/box/tab on the screen Sample labeled “Sample” which can be selected/executed by clicking.
  • Page 13: Table Of Contents

    Starting up E5091A........
  • Page 14 Contents Cleaning a Display Other than Interconnection Ports and Test Ports......54 Cautions Applicable to Requesting Repair, Replacement, Regular Calibration, etc....55 Devices to be Sent Back for Repair or Regular Calibration .
  • Page 15: Installation

    Installation This chapter describes the setup of this product.
  • Page 16: Incoming Inspection

    4. If you find any fault on the product during operational checks described below. In the case of 1, notify the carrier as well as your nearest Agilent Technologies sales office. Keep the shipping container, cushioning material, and the contents of the shipment for the...
  • Page 17 Installation Incoming inspection Figure 1-1 E5091A front panel...
  • Page 18 Installation Incoming inspection Table 1-1 Contents of the E5091A package Name Agilent product/part number ntity Standard contents E5091A E5091A N-type cable 8120-4782 USB cable 8121-0770 See Figure 1-8 Power cable E5091-905xx CD-ROM (of the manual) Option Manual (Option ABA) •...
  • Page 19 Installation Incoming inspection Figure 1-2 Accessories E5091A-009 Figure 1-3 Accessories E5091A-016...
  • Page 20: Requirements For Installation Environment

    Up to 0.5 G, 5 Hz to 500 Hz CAUTION The above operating environment does not mean the conditions under which all the specifications and measurement accuracy of the E5091A are satisfied but those under which the E5091A operates normally.
  • Page 21: Heat Dissipation Clearance

    Installation Requirements for installation environment Heat dissipation clearance To satisfy the safety, specifications, and measurement accuracy of the product, you need to keep the temperature around the product within a specific range by providing proper heat dissipation clearance around the product or by air-cooling the inside of the rack forcefully when you mount the product in the rack.
  • Page 22: Antistatic Measures

    As described in “Cutting supply of power” on page 23, the disconnecting device (the device to cut the supply of power) of the E5091A is the plug of the power cable. When installing the E5091A, provide sufficient clearance not to hinder the operation of disconnecting the plug of the power cable (on the power outlet side or the E5091A side) in an emergency to cut the supply of power.
  • Page 23: Mounting Front Handles/Flanges For Rackmount

    Mounting front handles/flanges for rackmount Mounting front handles/flanges for rackmount You can use the E5091A on a workbench or mounted in a rack. This section describes how to mount the front handles used to move/transport it (Option 1CN) and how to mount it into a rack as part of a measurement system (Option 1CM: without handles/Option 1CP: with handles).
  • Page 24: Mounting Handle Kit (Option 1Cn)

    Step 1. Remove the trim strips (1) stuck to both the sides of the front panel (stuck to the frame). Step 2. Mount the front handles (3) to both the sides of the front panel of the E5091A with the attached screws.
  • Page 25: Mounting Rackmount Kit (Option 1Cm)

    Step 2. Mount the front handles (3) and the flanges for rackmount (5) to both the sides of the front panel of the E5091A with the attached screws. Step 3. Remove the 4 legs on the bottom of the E5091A (pull up the part with the (TAB indication and slide it to the arrow direction).
  • Page 26: Power Supply And Fuse

    UL/CSA type, Slo-Blo, 5×20 mm miniature fuse, 3A 250V (Agilent part number: 2110-1017) Spare fuses are available from Agilent Technologies sales office. To check or replace the fuse, disconnect the power cable and pull out the fuse holder. Figure 1-7...
  • Page 27: Checking And Connecting Power Cable

    Power supply and fuse Checking and connecting power cable The power cable that comes with the E5091A has 3-wire structure and one of them is the grounding wire. This power cable grounds the E5091A through an outlet, protecting the operator from shock hazards.
  • Page 28 Installation Power supply and fuse Figure 1-8 Power cable options...
  • Page 29: Starting Up E5091A

    Installation Starting up E5091A Starting up E5091A This section describes how to turn ON/OFF the E5091A and how to cut the supply of power in an emergency. Turning ON/OFF the power Turning ON power Step 1. Check that the line switch in the lower left part of the front panel is pulled up ( ).
  • Page 30 Installation Starting up E5091A...
  • Page 31: Product Overview

    Product Overview This chapter describes the overview of the E5091A ENA Series multiport test set.
  • Page 32: About This Product

    Product Overview About this product About this product Agilent The E5091A is a multiport test set used by connecting to the ENA Series RF Network Analyzers. The main features of this instrument are: • The Agilent E5091A, controlled with the ENA Series RF Network Analyzers, lets you measure a multi-port DUT by making the connection once.
  • Page 33: Name And Function Of Each Part

    Indicates the test ports connected to the interconnection ports when connected to the analyzer. For T1, T2, and T3 of the E5091A-016, the above two LEDs turn on. In the same way, A1 for ANT and B1 for T4 also turn on.
  • Page 34 CAUTION Take anti-static precautions before performing operation Because semiconductor devices are used in the E5091A, electrostatic discharge could cause the inside of the instrument to be damaged. Therefore, take the anti-static precautions sufficiently before performing operation. 6. Test ports Used to connect the DUT.
  • Page 35 Product Overview Name and function of each part The test ports comply with Installation Category I as defined in IEC61010-1.
  • Page 36: Rear Panel

    2. ID bit switch The bit switch to set the ID of the E5091A required for control from the ENA Series RF Network Analyzers. You can set it to 1 or 2. It is set to 1 when shipped from the factory.
  • Page 37: Setting The Instrument

    Setting the Instrument This chapter describes the setting of the E5091A. For more information on the setting procedure, refer to ENA Series RF Network Analyzers Users Guide.
  • Page 38: Setting The Id

    Setting the ID In this section, the procedure to set the ID. Step 1. Set the line switch to OFF if the E5091A has been turned on. Step 2. Set the ID with the ID bit switch on the rear panel.
  • Page 39: Correlation Between Interconnection Port And Test Ports

    The following table shows the correlation of the test ports (A to Z2) available to the interconnection ports (port 1to port 7). Available test ports differ depending on the model used (E5091A-009/E5091A-016). The E5091A-016 provides the 13-port device and 16-port device measurement, whose available test ports differ. Table 3-1...
  • Page 40: Internal Block Diagram

    Setting the Instrument Internal block diagram Internal block diagram Figure 3-2 shows the block diagram inside the E5091A. Figure 3-2 Block diagram of the E5091A...
  • Page 41: Paths That Can Be Measured

    Setting the Instrument Internal block diagram Paths that can be measured Figure 3-2 shows the paths that the E5091A can measure based on Figure 3-3 or Figure 3-4. Figure 3-3 Paths that can be measured (E5091A-009)
  • Page 42 Setting the Instrument Internal block diagram Figure 3-4 Paths that can be measured (E5091A-016)
  • Page 43: Setting Control Line

    This section describes the electrical characteristics of the control line and the connection to a DUT and an external dc power supply. For more information on the control procedure, refer to "Controlling the E5091A" in ENA Series RF Network Analyzers Users Guide. Pin assignment Figure 3-5 and Table 3-2 show the pin assignment of the control line.
  • Page 44 Setting the Instrument Setting control line Table 3-2 Pin assignment Signal name Description number Line 1 The output port of Line 1. Line 2 The output port of Line 2. Line 3 The output port of Line 3. Line 4 The output port of Line 4.
  • Page 45: Specifications

    The output voltage of the pin 12 can be varied from +2 V to +5 V. To set the vlotage, perform the following procedure. Step 1. Turn on the E5091A. Step 2. Measure the voltage between the pin 12 and 15 by a multimeter.
  • Page 46: Connection To A Dut

    CAUTION the external power supply”. To turning off, perform the reverse procedure of it. The E5091A may break down if a dc current pass through the E5091A when it is turned off. CAUTION Don’t short-circuit between pins because it may be cause of faults.
  • Page 47 Setting the Instrument Setting control line Figure 3-8 Connecting the E5091A to the DUT and the external dc power supply...
  • Page 48: Operation Basics

    Setting the Instrument Operation basics Operation basics For more information on the connection and operation, refer to "Controlling the E5091A" in ENA Series RF Network Analyzers Users Guide.
  • Page 49: Specifications And Supplemental Information

    Specifications and Supplemental Information This chapter provides specifications and supplemental information for the Agilent E5091A.
  • Page 50: Definitions

    Specifications and Supplemental Information Definitions Definitions All specifications apply over a 18°C to 28°C range (unless otherwise stated) and 90 minutes after the instrument has been turned on. Specification (spec.): Warranted performance. Specifications include guardbands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions.
  • Page 51: Test Set Input/Output Performance

    Specifications and Supplemental Information Test Set Input/Output Performance Test Set Input/Output Performance This section provides test set input/output performance without calibration by the ENA Series RF Network Analyzers. Option 009 Description Specification Frequency Range 50 MHz to 8.5 GHz 20 dBm, ±25 V DC (Typical) Damage Level Frequency Description...
  • Page 52: Option 016

    Specifications and Supplemental Information Test Set Input/Output Performance Option 016 Description Specification Frequency Range 50 MHz to 8.5 GHz 20 dBm, ±25 V DC (Typical) Damage Level Frequency Description 50 MHz to 300 MHz to 1.3 GHz to 3 GHz to 6 GHz to 300 MHz 1.3 GHz...
  • Page 53: General Information

    Specifications and Supplemental Information General Information General Information Table 4-1 Connector Description Supplemental Information Front Panel Option 009: Type-N, female, 50 Ω (nominal) RF Connector Type Option 016: SMA, female, 50 Ω (nominal) Number of Ports Option 009: 13 (Interconnect Port 4, Test Port 9) Option 016: 29 (Interconnect Port 4, Test Port 25) Control Line 15 pin D-sub, female...
  • Page 54 Specifications and Supplemental Information General Information Table 4-3 EMC,Safety and Environment Description Supplemental Information European Council Directive 89/336/EEC EN / IEC 61326-1:1997+A1:1998 CISPR 11:1997+A1:1999 / EN 55011:1998+A1:1999 Group 1, Class A IEC 61000-4-2:1995 / EN 61000-4-2:1995 +A1:1998 4 kV CD / 4 kV AD IEC 61000-4-3:1995 / EN 61000-4-3:1996 +A1:1998 3 V/m, 80-1000 MHz, 80% AM IEC 61000-4-4:1995 / EN 61000-4-4:1995...
  • Page 55 Specifications and Supplemental Information General Information Table 4-4 Test set Environment and Dimensions Description Supplemental Information Operating Environment +5 °C to +40 °C Temperature 23 °C ± 5 °C with < 1°C deviation from calibration temperature Error-Corrected Temperature Range 0 % RH to 90% @<40 °C (non-condensing) Humidity Altitude 0 to 2,000 m (0 to 6,561 feet)
  • Page 56 Specifications and Supplemental Information General Information Figure 4-2 Dimensions (rear view, with Option 009, in millimeters, nominal) Figure 4-3 Dimensions (side view, with Option 009, in millimeters, nominal) Figure 4-4 Dimensions (front view, with Option 016, in millimeters, nominal) Chapter 4...
  • Page 57 Specifications and Supplemental Information General Information Figure 4-5 Dimensions (rear view, with Option 016, in millimeters, nominal) Figure 4-6 Dimensions (side view, with Option 016, in millimeters, nominal) Chapter 4...
  • Page 58 Specifications and Supplemental Information General Information Chapter 4...
  • Page 59: Information On Maintenance

    Information on Maintenance This chapter explains the measures you should take to maintain the Agilent E5091A.
  • Page 60: Cleaning This Instrument

    Never clean the internal components of the instrument. Maintenance of Interconnection Ports and Test Ports Interconnection ports and test ports on the front panel of the E5091A are fitted with N Type connectors (f). Stains or other damage to these connectors would significantly affect the accuracy in measurements in the RF range.
  • Page 61: Cautions Applicable To Requesting Repair, Replacement, Regular Calibration, Etc

    Regular Calibration, etc. Devices to be Sent Back for Repair or Regular Calibration If it is necessary to send the unit to the Service Center of Agilent Technologies for repair or regular calibration, please follow the instructions below. Equipment to be Sent When requesting repair or regular calibration of the unit by our Service Center, send only the E5091A main unit without any installed option you may have ordered.
  • Page 62 Information on Maintenance Cautions Applicable to Requesting Repair, Replacement, Regular Calibration, etc. Chapter 5...
  • Page 63: Manual Changes

    Manual Changes This appendix contains the information required to adapt this manual to versions or configurations of the E5091A manufactured earlier than the current printing date of this manual.
  • Page 64: Manual Changes

    Example of Serial Number Plate Change 1 Please note that option 007 (E5091A-007) is obsolete as of November 2005. To obtain the specifications of this product, refer to the following table. Option 016 (E5091A-016) is supported by the firmware version A.06.00 or higher of the ENA RF Network Analyzer (E5070B/E5071B).
  • Page 65 Manual Changes Manual Changes Frequency Description 50 MHz to 300 MHz to 1.3 GHz to 3 GHz to 6 GHz to 300 MHz 1.3 GHz 3 GHz 6 GHz 8.5 GHz Test Port Unselected A, T2, R1+, R1-, 23 dB 25 dB 19 dB 12 dB...
  • Page 66 Vibration 0.5 G maximum, 5 Hz to 500 Hz Weight, Dimension Dimension See Figure 4-1 on page 49 through Figure 4-3 on page 50. 6 kg (Option 007, Nominal) Figure A-2 Block diagram of the E5091A (Option 007) Appendix A...
  • Page 67 Manual Changes Manual Changes Figure A-3 Paths that the E5091A can be measured (Option 007) Appendix A...
  • Page 68 Manual Changes Manual Changes Appendix A...
  • Page 69 58 front handle space to disconnect the plug, 16 mounting, 18 specifications, 43 definitions, 44 Specified Torque, 28 starting up E5091A, 23 handle kit mounting, 19 history, manual printing, 2 test port, 33 Test Ports Maintenance, 54...
  • Page 70 REGIONAL SALES AND SUPPORT OFFICES For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative.

Table of Contents