Table 16: High-Capacity AC Power Supply LEDs
Label
Color
AC-1 OK
Green
AC-2 OK
Green
DC OK
Green
PS FAIL
Red

SRX5800 Services Gateway AC Power Supply Specifications

Table 17 on page 54
lists the AC power supply electrical specifications for both the standard-capacity and
high-capacity AC power supply.
Table 17: AC Power Supply Electrical Specifications
Item
Maximum output power
State
Description
Off
AC power applied to power supply at the upper appliance inlet is not within
the normal operating range.
On
AC power applied to power supply at the upper appliance inlet is within the
normal operating range.
Off
AC power applied to power supply at the lower appliance inlet is not within
the normal operating range.
On
AC power applied to power supply at the lower appliance inlet is within the
normal operating range.
Off
DC power outputs generated by the power supply are not within the normal
operating ranges.
On
DC power outputs generated by the power supply are within the normal
operating ranges.
Off
Power supply is functioning normally.
On
Power supply is not functioning normally. Check the AC-1 OK, AC-2 OK,
and DC OK LEDs for more information.
Table 18 on page 55
Specification
Standard-Capacity
1700 W
lists the AC power system electrical specifications.
High-Capacity
4100 W (two AC inputs)
1700 W (one AC input)