Troubleshooting The Srx5800 Services Gateway Power System - Juniper SRX5800 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5800:
Table of Contents

Advertisement

Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 1 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
Slot 2 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Max Power Consumption
For further description of the output from the command, see Junos OS System Basics and Services Command
Reference at www.juniper.net/documentation/.

Troubleshooting the SRX5800 Services Gateway Power System

Problem
Description: The power system is not functioning normally.
Solution
Check the LEDs on each power supply faceplate.
If an AC power supply is correctly installed and functioning normally, the AC OK and DC OK LEDs
light steadily, and the PS FAIL LED is not lit.
If a DC power supply is correctly installed and functioning normally, the PWR OK, BREAKER ON, and
INPUT OK LEDs light steadily.
35
1024 MB
259 MB
4864 MB
2013-12-10 02:58:16 PST
1 day, 11 hours, 59 minutes, 15 seconds
585 Watts
Online
47
1024 MB
259 MB
4864 MB
2013-12-10 02:55:30 PST
1 day, 12 hours, 2 minutes, 1 second
585 Watts
Online
37
2048 MB
1036 MB
6656 MB
2013-12-10 02:58:07 PST
1 day, 11 hours, 59 minutes, 24 seconds
570 Watts
449