and pressed as far as possible toward the center of the board. Once you have installed an SCB, place
the ejector handles in their proper position, vertically and toward the center of the board. To avoid
blocking the visibility of the LEDs,position the ejectors over the PARK icon.
To insert or remove the SCB card, slide the ejector across the SCB horizontally, rotate it, and slide it
again another quarter of a turn. Turn the ejector again and repeat as necessary. Use the indexing feature
to maximize leverage and to avoid hitting any adjacent components.
Operate both ejector handles simultaneously. The insertion force on an SCB is too great for one ejector.

Replacing an SRX5800 Services Gateway SCB

Before replacing an SCB, read the guidelines in
SCB Ejectors" on page
306. To replace an SCB, perform the following procedures:
NOTE:
The procedure to replace an SCB applies to the SRX5K-SCB, SRX5K-SCBE, SRX5K-SCB3,
and SRX5K-SCB4.

Removing an SRX5800 Services Gateway SCB | 307

1.
Installing an SRX5800 Services Gateway SCB | 309
2.
Removing an SRX5800 Services Gateway SCB
Before you begin to remove a SCB:
Ensure you understand how to prevent electrostatic discharge (ESD) damage. See
Electrostatic Discharge Damage" on page
Ensure that you have the following available:
ESD grounding strap
Replacement SCB or blank panel
Antistatic mat
"Operating and Positioning the SRX5800 Services Gateway
505.
"Prevention of
307