Replacing Srx5800 Services Gateway Spcs; Removing An Srx5800 Services Gateway Spc - Juniper SRX5800 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5800:
Table of Contents

Advertisement

CAUTION:
An arc smaller than a few inches in diameter can damage the cable and cause
problems that are difficult to diagnose.
12. Power on the services gateway.
13. Use one of the following methods to take the port module online:
Insert a pointed tool into the ONLINE pinhole on the front panel of the port module to press the
button behind it. Hold the button down until the OK/FAIL LED at the opposite end of the front panel
lights green steadily, in about 5 seconds.
Issue the following CLI command:
user@host>request chassis fpc-slot slot-number pic-slot slot-number online
For more information about the command, see Junos OS System Basics and Services Command Reference
at www.juniper.net/documentation/.
CAUTION:
removing the port module again, removing a port module from a different slot,
or inserting a port module in a different slot.
You can also verify that the port module is functioning correctly by issuing the show chassis fpc and
show chassis fpc pic-status commands.

Replacing SRX5800 Services Gateway SPCs

To replace an SPC, perform the following procedures:

Removing an SRX5800 Services Gateway SPC | 360

1.
Installing an SRX5800 Services Gateway SPC | 363
2.
Removing an SRX5800 Services Gateway SPC
An SPC weighs up to 18.3 lb (8.3 kg). Be prepared to accept its full weight.
Before you begin to remove a SPC:
Avoid bending a fiber-optic cable beyond its minimum bend radius.
After the OK/FAIL LED turns green, wait at least 30 seconds before
360

Advertisement

Table of Contents
loading

Table of Contents