Table 40: SRX5800 Services Gateway Power Requirement with 8xSPC3 and 3xIOC4
Zone
Chassis Component
Zone
High-capacity cooling
1
system (Upper Fan
Tray)
SPC - slots 0 through 3
IOC - slots 4 and 5
SCB 0
Zone
SCB 1
0
SCB 2/Slot 6
SPC - slots 7 through
10
IOC - slot 11
High-capacity cooling
system (Lower Fan
Tray)
Total power allocation
Power Budget
Part Number
(default)
SRX5800-HC-FAN
320 W
SPC3
650 W * 4
=2600 W
IOC4
545 W * 2
=1090 W
SCB3 with RE2
275 W
SCB3 with RE2
275 W
SCB3
185 W
SPC3
650 W * 4
=2600 W
IOC4
545 W
SRX5800-HC-FAN
320 W
8210 W
Power Budget at
Power budget
Ambient
(with 25° C
Temperature
config)
(25° C)
320 W
320 W
615 W * 4
614.5 W * 4
=2460 W
=2458 W
440 W * 2
440 W * 2 =880 W
=880 W
275 W
245 W
275 W
245 W
185 W
155 W
615 W * 4
614.5 W * 4
=2460 W
=2458 W
440 W
440 W
320 W
320 W
7615 W
7521 W