6. Arrange the cable to prevent it from dislodging or developing stress points. Secure the cable so that it
is not supporting its own weight as it hangs to the floor. Place excess cable out of the way in a neatly
coiled loop.
CAUTION:
An arc smaller than a few inches in diameter can damage the cable and cause
problems that are difficult to diagnose.
7. On the MPC, pull the ejector knob that is adjacent to the MIC you are removing away from the MPC
faceplate. The ejector knob is located between the MIC and the rotational knob that retains the MPC
in the services gateway card cage. Pulling the ejector knob unseats the MIC from the MPC and partially
ejects it. See
Figure 145 on page
Avoid bending a fiber-optic cable beyond its minimum bend radius.
379.