Juniper SRX5800 Hardware Manual page 327

Services gateway
Hide thumbs Also See for SRX5800:
Table of Contents

Advertisement

available to take over network traffic.
root@cluster> show version node1
Hostname: <displays the hostname>
Model: <displays the model number>
Junos: 15.1X49-D10
JUNOS Software Release [15.1X49-D10]
root@cluster> show chassis cluster status
Monitor Failure codes:
CS
Cold Sync monitoring
GR
GRES monitoring
IF
Interface monitoring
LB
Loopback monitoring
NH
Nexthop monitoring
SP
SPU monitoring
CF
Config Sync monitoring
Cluster ID: 1
Node
Priority Status
Redundancy group: 0 , Failover count: 1
node0
0
lost
node1
100
primary
Redundancy group: 1 , Failover count: 3
node0
0
lost
node1
150
primary
root@cluster>show chassis fpc pic-status node1
Slot 1
Online
PIC 0
Online
PIC 2
Online
Slot 2
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 3
Online
FL
Fabric Connection monitoring
HW
Hardware monitoring
IP
IP monitoring
MB
Mbuf monitoring
NP
NPC monitoring
SM
Schedule monitoring
Preempt Manual
n/a
n/a
no
no
n/a
n/a
no
no
SRX5k IOC II
1x 100GE CFP
2x 40GE QSFP+
SRX5k SPC II
SPU Cp
SPU Flow
SPU Flow
SPU Flow
SRX5k IOC II
Monitor-failures
n/a
None
n/a
None
328

Advertisement

Table of Contents
loading

Table of Contents