Maintaining Interface Cards and SPCs on the SRX5800 Services Gateway

Purpose
For optimum services gateway performance, verify the condition of the Services Processing Cards (SPCs)
and interface cards (IOCs, Flex IOCs and MPCs). The services gateway can have up to 11 SPCs and interface
cards. To maintain SPCs and interface cards, perform the following procedures regularly.
Action
On a regular basis:
Check the LEDs on the craft interface corresponding to the slot for each SPC and interface card. The
green LED labeled OK lights steadily when a card is functioning normally.
Check the OK/FAIL LED on the faceplate of each SPC and interface card. If the card detects a failure,
it sends an alarm message to the Routing Engine.
Issue the CLI show chassis fpc command to check the status of installed cards. As shown in the sample
output, the value Online in the column labeled State indicates that the card is functioning normally:
user@host> show chassis fpc
Temp
CPU Utilization (%)
Slot State
0
Online
1
Online
2
Online
3
Empty
4
Empty
5
Online
For more detailed output, add the detail option. The following example does not specify a slot number,
which is optional:
user@host> show chassis fpc detail
Slot 0 information:
State
Temperature
Total CPU DRAM
Total RLDRAM
Total DDR DRAM
Start time:
Uptime:
Slot 1 information:
Memory
(C)
Total
Interrupt
41
9
43
5
43
11
42
6
1024 MB
256 MB
4096 MB
Utilization (%)
DRAM (MB) Heap
0
1024
15
0
1024
16
0
1024
16
0
1024
16
Online
41 degrees C / 105 degrees F
2007-07-10 12:28:33 PDT
1 hour, 33 minutes, 52 seconds
Buffer
57
57
57
57
340