Juniper SRX5800 Hardware Manual page 116

Services gateway
Hide thumbs Also See for SRX5800:
Table of Contents

Advertisement

LEDs
OK/FAIL LED, one bicolor:
Steady green–The SPC is operating normally.
Red–The SPC has failed and is not operating normally.
Off–The SPC is powered down.
STATUS LED, one tricolor for each SPU SPU 0 and SPU 1:
Off–The SPU is offline.
Blinking Amber–The SPU is initializing.
Green–The SPU initialization is done and it is operating normally.
Red–The SPU has encountered an error or a failure.
SERVICE LED, one tricolor for each SPU SPU 0 and SPU 1:
Off–The SPU is offline.
Blinking Red–The SPU initialization is done.
Blinking Amber–Service is initializing on the SPU.
Green–Service is running on the SPU under acceptable load.
Solid Red–Service encountered an error or a failure.
HA LED, one tricolor:
Green–Clustering is operating normally. All cluster members and monitored links are available,
and no error conditions are detected.
Red–A critical alarm is present on clustering. A cluster member is missing or unreachable, or the
other node is no longer part of a cluster because it has been disabled by the dual membership
and detection recovery process in reaction to a control-link or fabric-link failure.
Amber–All cluster members are present, but an error condition has compromised the performance
and resiliency of the cluster. The reduced bandwidth could cause packets to be dropped or could
result in reduced resiliency because a single point of failure might exist. The error condition might
be caused by:
The loss of chassis cluster links which causes an interface monitoring failure.
An error in an SPU or NPU.
Failure of the spu-monitoring or cold-sync-monitoring processes.
A chassis cluster IP monitoring failure.
Off–The node is not configured for clustering or it has been disabled by the dual membership
and detection recovery process in reaction to a control link or fabric link failure.
LINK/ACT LED, one for each of the two ports CHASSIS CLUSTER CONTROL 0 and CHASSIS
CLUSTER CONTROL 1:
Green–Chassis cluster control port link is active.
Off–No link.
117

Advertisement

Table of Contents
loading

Table of Contents