Maintaining the SRX5800 Chassis

IN THIS SECTION

Routine Maintenance Procedures for the SRX5800 Services Gateway | 263

Replacing the SRX5800 Services Gateway Craft Interface | 263

Routine Maintenance Procedures for the SRX5800 Services Gateway
Purpose
For optimum services gateway performance, perform preventive maintenance procedures regularly.
Action
Inspect the installation site for moisture, loose wires or cables, and excessive dust. Make sure that airflow
is unobstructed around the device and into the air intake vents.
Check the status-reporting devices on the craft interface—System alarms and LEDs.
Inspect the air filter at the bottom front of the services gateway, replacing it every six months for optimum
cooling system performance. Do not run the device for more than a few minutes without the air filter
in place.
Replacing the SRX5800 Services Gateway Craft Interface
To replace the craft interface, perform the following procedures in sequence:

Disconnecting the Alarm Relay Wires from the SRX5800 Services Gateway Craft Interface | 263

1.
Removing the SRX5800 Services Gateway Craft Interface | 264
2.
Installing the SRX5800 Services Gateway Craft Interface | 265
3.
Connecting the Alarm Relay Wires to the SRX5800 Services Gateway Craft Interface | 266
4.
Disconnecting the Alarm Relay Wires from the SRX5800 Services Gateway Craft Interface
Before you begin disconnecting the alarm relay wires from the services gateway and an alarm-reporting
device: