SRX5400 Services Gateway AC Power Specifications and Requirements

SRX5400 Services Gateway AC Power Supply Specifications

Table 29: AC Power Supply Electrical Specifications
Item
Maximum output power
AC input current rating
AC input voltage
AC input line frequency
Table 30: AC Power System Specifications
Item
Redundancy
Output power (maximum) per power supply
Output power (maximum) per system
Related
Documentation
194
WARNING:
To meet safety and electromagnetic interference (EMI)
requirements and to ensure proper operation, you must properly ground the
services gateway chassis before connecting power. See
SRX5400 Services Gateway" on page 64
SRX5400 Services Gateway Chassis Grounding Point Specifications on page 192
SRX5400 Services Gateway Grounding-Cable Lug Specification on page 193
SRX5400 Services Gateway AC Power Supply Specifications on page 194
AC Power Circuit Breaker Requirements for the SRX5400 Services Gateway on page 195
AC Power Cord Specifications for the SRX5400 Services Gateway on page 195
Table 29 on page 194
lists the AC power supply electrical specifications.
Table 30 on page 194
lists the AC power system electrical specifications.
Specification
1167 W (low line)
2050 W (high line)
16 A @ 110 VAC maximum
15.1 A @ 200 VAC maximum
Operating range: 100 - 240 VAC (nominal)
50 to 60 Hz (nominal)
Calculating Power Requirements for the SRX5400 Services Gateway on page 189
Low-Line (110V)
2+1
1167 W
3501 W
"Grounding the
for instructions.
High-Line (220V)
2+1
2050 W
4100 W