Juniper SRX5800 Hardware Manual page 403

Services gateway
Hide thumbs Also See for SRX5800:
Table of Contents

Advertisement

To replace a Routing Engine on node 0 of a chassis cluster using a USB flash drive:
1. Prepare to shut down node 0:
a. Perform a manual failover of the redundancy groups (RGs) from node 0 to node 1.
Fail over RG1:
root@node0> request chassis cluster failover redundancy-group 1 node 1
Fail over RG0:
root@node0> request chassis cluster failover redundancy-group 0 node 1
b. Verify that both RGs are active on node 1 after the failover:
root@node0> show chassis cluster status
{secondary:node0}
root@node0> show chassis cluster status
Monitor Failure codes:
CS
Cold Sync monitoring
GR
GRES monitoring
IF
Interface monitoring
LB
Loopback monitoring
NH
Nexthop monitoring
SP
SPU monitoring
CF
Config Sync monitoring
Cluster ID: 1
Node
Priority Status
Redundancy group: 0 , Failover count: 1
node0
129
node1
255
Redundancy group: 1 , Failover count: 1
node0
129
node1
255
Preempt Manual
secondary
no
primary
no
secondary
no
primary
no
FL
Fabric Connection monitoring
HW
Hardware monitoring
IP
IP monitoring
MB
Mbuf monitoring
NP
NPC monitoring
SM
Schedule monitoring
RE
Relinquish monitoring
Monitor-failures
no
None
no
None
no
None
no
None
404

Advertisement

Table of Contents
loading

Table of Contents