Srx5800 Services Gateway Chassis - Juniper SRX5800 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5800:
Table of Contents

Advertisement

SRX5800 Services Gateway Craft Interface Fan LEDs | 39
SRX5800 Services Gateway Craft Interface Online Buttons | 39
SRX5800 Services Gateway Craft Interface Alarm Relay Contacts | 42

SRX5800 Services Gateway Chassis

The services gateway chassis is a rigid sheet metal structure that houses all the other services gateway
components (see
Figure 1 on page
27.75 in. (70.49 cm) high, 17.37 in. (44.11 cm) wide, and 23.0 in. (58.42 cm) deep (from the front-mounting
flanges to the rear of the chassis). The chassis installs in 19-in. equipment racks or telco open-frame racks.
The chassis can be installed in standard 800-mm (or deeper) enclosed cabinets when powered by
standard-capacity power supplies, or in 1000-mm (or deeper) enclosed cabinets when powered by
high-capacity power supplies.
Up to three services gateways can be installed in one standard (48 U) rack if the rack can handle their
combined weight, which can be greater than 1,134 lb (515 kg). See
Specifications" on page 32
Mounting hardware includes front-mounting flanges on the front of the chassis, and two center-mounting
brackets attached to the center of the chassis.
WARNING:
to ensure proper operation, you must properly ground the services gateway chassis
before connecting power. See
for instructions.
CAUTION:
an ESD strap to an ESD point and place the other end of the strap around your bare
wrist. Failure to use an ESD strap can result in damage to the services gateway.
30,
Figure 2 on page
for physical specifications for the SRX5800 Services Gateway.
To meet safety and electromagnetic interference (EMI) requirements and
"Grounding the SRX5800 Services Gateway" on page 239
Before removing or installing components of a services gateway, attach
31, and
Figure 3 on page
32). The chassis measures
"SRX5800 Services Gateway Physical
29