Table 59: Estimated Values for Factors That Cause Link Loss (continued)
Link-Loss Factor
Modal and chromatic dispersion
Connector
Splice
Fiber attenuation
The following example uses the estimated values in
2 km-long multimode link with a power budget (P
Fiber attenuation for 2 km @ 1.0 dB/km= 2 dB
Loss for five connectors @ 0.5 dB per connector = 5(0.5 dB) = 2.5 dB
Loss for two splices @ 0.5 dB per splice =2(0.5 dB) = 1 dB
Higher-order loss = 0.5 dB
Clock recovery module = 1 dB
The power margin (P
) is calculated as follows:
M
P
= P
– LL
M
B
P
= 13 dB – 2 km (1.0 dB/km) – 5 (0.5 dB) – 2 (0.5 dB) – 0.5 dB [HOL] – 1 dB [CRM]
M
P
= 13 dB – 2 dB – 2.5 dB – 1 dB – 0.5 dB – 1 dB
M
P
= 6 dB
M
The following sample calculation for an 8 km-long single-mode link with a power budget (P
the estimated values from
(8 km @ 0.5 dB/km, or 4 dB) and loss for seven connectors (0.5 dB per connector, or 3.5 dB). The power
margin (P
) is calculated as follows:
M
P
= P
– LL
M
B
P
= 13 dB – 8 km (0.5 dB/km) – 7 (0.5 dB)
M
P
= 13 dB – 4 dB – 3.5 dB
M
Estimated Link-Loss Value
Single-mode—None
Multimode—None, if product of bandwidth and distance is less
than 500 MHz–km
0.5 dB
0.5 dB
Single-mode—0.5 dB/km
Multimode—1 dB/km
) of 13 dB:
B
Table 59 on page 200
to calculate link loss (LL) as the sum of fiber attenuation
Table 59 on page 200
to calculate link loss (LL) for a