NEC Univerge NEAX 2000 IPS Command Manual page 457

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE
43
Y
MEANING
5 Time setting for regu-
lar system data backup
6 Time setting for
term
D
IP firmware
automatic update
[Series 3200 R6.1
(R6.1)]
7 Start time for copying
the office data from
the Main Site to
Remote Sites
[Series 3200 R6.2
(R6.2)]
NOTE 1:
Office data copy is executed from the low Remote Site number to high Remote Site number.
NOTE 2:
The start time for office data copy may gain/loss about three minutes from the time you set.
8 Time setting for
Automatic clock
change
[Series 3600]
TITLE:
PERIODIC MAINTENANCE/OFFICE DATA PERIODIC COPY IN BACKUP CPU
term
SYSTEM/D
IP FIRMWARE AUTOMATIC UPDATE/OFFICE DATA COPY
1ST
MEANING
DATA
00
Regular backup time
term
00
D
IP firmware auto-
matic update time
00
Office data copy
00
Time setting for
automatic system clock
change from standard
time to daylight-saving
time
(for change pattern 0)
01
Time setting for auto-
matic system clock
change from daylight-
saving time to standard
time
(for change pattern 0)
2ND DATA
HH MM
9999
NONE
YYYY MM DD HH mm
NONE
HH MM
9999
NONE
MM W D
NONE
– 433 –
CM43
: Initial Data
MEANING
HH : Hour (00-23)
MM : Minute (00-59)
No backup the office data
0300 (3:00 a.m.)
YYYY: Year (2000-2099)
MM
: Month (01-12)
DD
: Day (01-31)
HH
: Hour (00-23)
mm
: Minutes (00-59)
No data
HH : Hour (00-23)
MM : Minute (00-59)
Not copy the office data
automatically
0200 (2:00 a.m.)
MM: Change Month (01-12)
W : Change Week (1-4/9)
First-Fourth Week
(1-4)
Final Week (9)
D
: Change Day of the
week (0-6)
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
Automatic clock change is
not provided
Continued on next page
NWA-008844-001 Rev.5.0
91ch3004.fm
JULY/01/2006

Advertisement

Table of Contents
loading

Table of Contents