COMMAND CODE TITLE:
EA
Y
No.
MEANING
2
Fault information
store into memory,
and control of
external alarm
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
1ST DATA
DATA
MEANING
Fault Kind: Occurrence
01
System Initialization
04
MP-FP/AP communication fail-
ure
08
FP/AP card down
09
Power failure
12
CS/ZT fault occurred
16
Periodic maintenance
20
DTI line failure
21
DCH/BRT/PRT D-channel link
connection failure
22
CCH link connection failure
CCH/IPT link connection fail-
ure
[Series 3300 software
required]
24
Number of faulty trunks was
more than predetermined num-
ber
[Australia Only]
25
Number of lockout stations was
more than predetermined num-
ber
26
DLC card down
28
SMDR output buffer memory
overflow
2B
CS/ZT fault occurred
2C
LAN application fault occurred
[Series 3400]
2ND DATA
DATA
0
External Alarm Kind
0: Fault Memory
3
NOTE 1
1: Fault Memory
2: Fault Memory
3: Fault Memory
NONE
No Fault Memory
store/No External
NOTE 2
Alarm output
To assign NONE,
enter CCC.
NOTE 3
NOTE 4
NOTE 5
– 727 –
: Initial Data
RELATED
COMMAND
MEANING
CM08>450, 451
store/No output of
CM42>01, 50
External Alarm
store/External
Alarm is MN
alarm
store/External
Alarm is MJ
alarm
store/External
Alarm Kind is
determined by
standard data
[See 2: External
Alarm Kind (MJ/
MN/– –)]
Page 739
Continued on next page
NWA-008844-001 Rev.5.0
DECEMBER/02/2005
CMEA
91ch3008.fm

Advertisement

Table of Contents
loading