COMMAND CODE TITLE:
38
INCOMING/OUTGOING TRUNK
Y
ROUTE No.
AMP PATTERN No.
01
AMP pattern number 00
AMP pattern number 14
02
03
04
05
06
07
AMP TRUNK CONTROL
DATA
X Z
0
1
0
1
0
1
0
1
0
1
0
1
SETTING DATA
MEANING
Assignment of Gain value
X: AGC (Automatic Gain Control)
0 : 0 dbr
1 : + 4 dbr
2 : – 4 dbr
3 : Through (Assigned by Fixed Gain)
Z: Fixed Gain
0 : 12 dB
1 : 8 dB
2 : 4 dB
3 : 0 dB
Echo Canceller function
Through
Normal
Echo Canceller Gain Controller
ON
OFF
Mode selection of Tone Disabler
G164
G165
Detect time of Tone Disabler
0 second
2 seconds
Channel to be connected
Incoming Route: Tie Line
Outgoing Route: C.O. Line
Incoming Route: C.O. Line
Outgoing Route: Tie Line
Timing of AMP trunk connection
When dialing is finished
When answering
NOTE:
The data 0 is effective except ISDN
and CCIS trunks.
– 381 –
CM38
: Initial Data
RELATED
COMMAND