NEC Univerge NEAX 2000 IPS Command Manual page 704

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
BA
Y
No.
MEANING
44
E.164 Address (Change
the calling number to
E.164 Address)
NOTE:
CMBA Y=44 must be set when the Gatekeeper requires E.164 Address as the ID Address of the
Gateway. If not, set this data to "15".
H.323/SIP PROFILE DATA
1ST DATA
DATA
MEANING
00
Profile number
for control packet
31
2ND DATA
DATA
00
Provide E.164
Address
01
Provide E.164
Address when the
calling number is not
set/Not provide E.164
Address when the
calling number is sent
02
When the calling
number is sent from
the trunk, the number
is used as the calling
number
[Series 3600]
03
No calling number/
When the calling
number is sent from
the trunk, the number
is used as the calling
number
[Series 3600]
15
E.164 Address is not
provided
– 680 –
: Initial Data
RELATED
COMMAND
MEANING
CM12 Y=12,
46
CMA7 Y=71
CMBA Y=32
Continued on next page
NWA-008844-001 Rev.5.0
NOVEMBER/15/2006
CMBA
91ch3007.fm