COMMAND CODE TITLE:
EA
Y
No.
MEANING
3
Sending fault infor-
mation by alarm
kind automatically
to 2400 IPX MAT/
RMAT/Centralized
MAT
4
Contents of fault
information sent to
2400 IPX MAT/
RMAT/Centralized
MAT
5
Office name sent to
2400 IPX MAT
FAULT INFORMATION STORE/DISPLAY FUNCTIONS
1ST DATA
DATA
MEANING
00
MJ Alarm*
01
MN Alarm*
02
– – Alarm*
*: External Alarm Kind set by CMEA
Y=2
00
Office number sent to RMAT
01
Destination of fault information
05
Destination point code of fault
information to 2400 IPX MAT/
Centralized MAT
01
Character Code
02
Character
2ND DATA
DATA
0
Send
1
Not sent
00
Office number
999
NONE
No data
2
2400 IPX MAT/
Centralized MAT
3
2400 IPX MAT/
Centralized MAT +
RMAT
7
RMAT
00001
Point Code
16367
NONE
No data
20-DF
Maximum 32 digits
NONE
No data
XX...XX
Office Name
Maximum 16 char-
acters
NONE
No data
– 731 –
: Initial Data
RELATED
COMMAND
MEANING
CMEA Y=2
See
Character
Code Table in
CM77.
Continued on next page