NEC Univerge NEAX 2000 IPS Command Manual page 354

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
31
Y
DATA
1
0
MFC PAD Control to Backward Signal
[Other than North America]
MF PAD Control to incoming signal
[North America Only]
1
Sensitive Level of MFC Receiver
[Other than North America]
Sensitive Level of MF Receiver
[North America Only]
2
Number of received digits of called
number from PSTN/T1 network
MFC/MF-ANI TRUNK DATA
1ST DATA
MEANING
INITIAL
INITIAL
INITIAL
DATA
0
–8 dBm
1
–10 dBm
2
–11.5 dBm
3
–9.13 dBm
4
Not used
7
00
–26 dBm
01
–27 dBm
02
–28 dBm
03
–29 dBm
04
–30 dBm
05
–31 dBm
06
–32 dBm
07
–33 dBm
08
–34 dBm (ITU-T Standard)
09
–35 dBm
10
–36 dBm
11
–37 dBm
12
–39 dBm
13
–40 dBm
14
–41 dBm
15
–38 dBm
00
–21 dBm
14
–35 dBm
15
–36 dBm
(–1 dBm increments)
NONE
No data
01
1 digit
31
31 digits
– 330 –
: Initial Data
2ND DATA
MEANING
Continued on next page