NEC Univerge NEAX 2000 IPS Command Manual page 183

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
0B
NOTE 1:
To provide the VLAN function to the system, clear the IP Address and Subnet Mask for the
system that has been set by CM0B Y=00>00 and 01 after setting the data by CM0B Y=02>03
and 04.
NOTE 2:
This data is only available to PZ-M606-A (ETHER) card.
NOTE 3:
This data is available when location number is not assigned by CM12 Y=39, 50.
NOTE 4:
For the visitor station in the visitor site, the tenant number set by this data is effective, even if
the tenant number has been set by CM12 Y=04.
NOTE 5:
This data must be set to the MP cards of each Remote Site.
NOTE 6:
Since this data is written to the Flash Rom of MP card directly, the data cannot be saved/load-
ed/verified. But the data can be cleared by the system data memory all clear.
LAN DATA ASSIGNMENT
– 159 –
CM0B
INITIAL
Continued on next page