NEC Univerge NEAX 2000 IPS Command Manual page 374

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
35
Y
No.
MEANING
15
Kind of call termination
indicator key/lamp on Atten-
dant Console
Call termination indicator
lamps further categorized by
the kind of calls (ex.C.O
incoming call or Tie line
incoming call).
NOTE 1:
When the standard lamp indications are utilized, set the standard data.
NOTE 2:
Set the correspondence between the key positions on Attendant Console and this assignment data by
CM46 or CM90.
16
Sending of Hook Flash to
outside
TRUNK ROUTE DATA
DATA
00
C.O. Incoming Call 0 (Standard "LDN" key)
07
C.O. Incoming Call 7
10
FX Incoming Call 0 (Standard "FX" key)
[North America Only]
17
FX Incoming Call 7
20
WATS Incoming Call 0
(Standard "WATS" key)
[North America Only]
27
WATS Incoming Call 7
30
CCSA Incoming Call 0
(Standard "CCSA" key)
[North America Only]
37
CCSA Incoming Call 7
40
Tie Line Incoming Call 0
(Standard "TIE" key)
47
Tie Line Incoming Call 7
75
Call Termination via No. 7 CCIS
NONE
No data
0
Not sending
1
Sending
SETTING DATA
MEANING
– 350 –
CM35
: Initial Data
RELATED
COMMAND
CM46
CM90
CM50
CM90 Y=00:
F1009
CM41 Y=2>17
Continued on next page
NWA-008844-001 Rev.5.0
91ch3003.fm
NOVEMBER/15/2006

Advertisement

Table of Contents
loading