NEC Univerge NEAX 2000 IPS Command Manual page 814

Internet protocol server
Hide thumbs Also See for Univerge NEAX 2000 IPS:
Table of Contents

Advertisement

COMMAND CODE TITLE:
D000
DATA
123
Clear of the call records which have been printed out
NOTE:
Effective when CMD000>16: 1 or CMD001>128: 1.
126
Control of External alarm relay (DK) when the accumulation
rate of billing memory exceeds the value set by CMD001>229
128
Display of the totaled bill of call records on group basis
NOTE:
Effective when CMD001>122: 1.
134
Send Wake Up message to PMS when setting Wake Up
135
Send result of Wake Up message when performing Wake Up call
136
Send text (Message Waiting control text sending is available) to
VMS when resetting AP00
137
Number of digits for station number in the message format to
communicate with VMS
140
Send Violation Code message when PBX receives an illegal mes-
sage from PMS
141
Send Violation Code message when PBX receives an undefined
FTC message from PMS
142
Send Violation Code message when PBX receives an undefined
FC message from PMS
143
Send ANI/Caller ID to SMDR
150
Maid Status Record Printout
SMDR/CIS/PMS FUNCTIONS (1)
1ST DATA
FUNCTION
0 : Not available
1 : Available
0 : Relay ON/OFF
See
CMD001>229
1 : Relay ON
0 : Not available
1 : Available
0 : Not sent
1 : To send
0 : Not sent
1 : To send
0 : To send
1 : Not sent
0 : 6 digits
1 : 8 digits
0 : Not sent
1 : To send
0 : Not sent
1 : To send
0 : Not sent
1 : To send
0 : Not sent
1 : To send
NOTE:
0 : Not available
1 : Available
– 790 –
: Initial Data
2ND DATA
(every 0.5 seconds)
When 0 is set, the ANI is not
sent to SMDR, but area code
for calling party, area code for
called party; authorization
code is sent to the SMDR.
Continued on next page
NWA-008844-001 Rev.5.0
CMD000
91ch3009.fm

Advertisement

Table of Contents
loading