COMMAND CODE TITLE:
42
KIND OF SYSTEM COUNTER
14
Number of times of Call
Forwards in Multiple-Call
Forwarding
15
Maximum number of calls in queue in each
UCD group for controlling external indicator
or Call Waiting lamp of D
16
Maximum number of calls in queue in each
UCD group before busy tone is provided
19
Number of times for recall from MP built-in
modem
47
Volume Control of D
(Sending level: Terminal to PBX)
[Europe Only]
48
Volume Control of D
(Receiving level: PBX to Terminal)
[Europe Only]
NOTE:
Careful consideration on the data settings is required because incorrect data settings may
cause howler of low-level speech.
SYSTEM COUNTER DATA
term
term
/Desk Console
INITIAL
NOTE
term
/Desk Console
INITIAL
NOTE
SETTING DATA
01
1 time
05
5 times
5 times
NONE
01
1 call
99
99 calls
1 call
NONE
01
1 call
99
99 calls
No limit
NONE
01
1 time
09
9 times
4 times
NONE
00
–56 dB
2 dB
25
0 dB
increments
31
+8 dB
0 dB
NONE
00
–48 dB
2 dB
23
0 dB
increments
31
+16 dB
0 dB
NONE
– 412 –
CM42
: Initial Data
REMARKS
Continued on next page
NWA-008844-001 Rev.5.0